Multi-Fuel
Boilers
INOV8 was the first in the waste oil burning industry to offer a boiler
capable of burning waste oil as its fuel. Now a decade later we have
a full line of high quality fully cleanable cast iron boilers ranging
from 200,000 to 1,000,000 BTUs per hour. The German made sectional
boiler has a front door that the burner mounts onto. When opened you
have full access to the nozzle, the combustion chamber and all flue
passageways for easy removal of ash. The boilers offer unlimited heating
options for businesses that generate waste oil. |
| The same INOV8 burner used with furnaces and evaporators
provides unequaled safety, reliability and the cleanest emissions
in the industry. When the boiler is operating there will be no smoke
and no blackened chimney. The average boiler efficiency is 85%. In-floor
radiant heat typically saves 25 to 40% over conventional heating methods.
That efficiency combined with burning waste oil; you can virtually
eliminate all heating bills. Businesses are further benefiting in
ways that would otherwise be too cost prohibitive with conventional
fuels.
INOV8 boilers are being used in a variety of businesses: in marinas,
green houses, quick lubes,
car washes, truck stops, factories, wood kilns, an electric utility
company, and in lots of car/truck dealerships and service companies.
INOV8 engineers provide free assistance in plan design and equipment
selection.
|

Cleaning accessibility is made easy with the swing door on the combustion
chamber. In fact, the boiler can be thoroughly and properly
cleaned in a fraction of the time is takes to
clean a conventional boiler, since it does not require disassembly. |
Boilers can be sized to meet any heat load requirement.
Multiple installations are great for staging boilers to meet varying
loads. INOV8 has developed a relay specifically for staging multiple
boilers so that the last boiler on is also the last boiler that
shuts off. This distributes the load evenly between the boilers. |
| INOV8 International boiler packages are the combination of a Buderus
boiler that has some modifications to accept an INOV8 burner and to
handle the unusual characteristics of waste oil as its fuel. The output
of the boilers may vary based on the type of waste oil. The boilers
shall be of full three-pass design, suitable for forced draft firing
and capable of achieving combustion efficiencies of 85% at full firing
rate. The boiler shall bear the ASME stamp and IBR rating. The INOV8
burner shall bear the Underwriters Laboratory listing in the United
States and in Canada. |
| |
Boiler Dimensions |
|
Burner Dimensions |
| Model |
Input BTU |
GPH |
Height |
Width |
Length |
Boiler Dry
Weight |
Water Connection |
Burner
Model |
Height |
Width |
Length |
| B225 |
225,000 |
1.60 |
34" |
23" |
51" |
600 |
1-1/2" |
BO-200 |
14" |
18" |
16" |
| B275 |
275,000 |
1.96 |
34" |
23" |
56" |
700 |
1-1/2" |
BO-201 |
14" |
18" |
17" |
| B325 |
325,000 |
2.32 |
34" |
23" |
61" |
800 |
1-1/2" |
BO-202 |
14" |
18" |
18" |
| B400 |
400,000 |
2.85 |
41" |
35" |
60" |
1,197 |
2" |
BO-203 |
14" |
18" |
19" |
| B500 |
500,000 |
3.50 |
41" |
35" |
66" |
1,391 |
2" |
BO-204 |
14" |
18" |
20" |
| B650 |
650,000 |
4.60 |
41" |
35" |
73" |
1,585 |
2" |
BO-205 |
14" |
18" |
21" |
| B750 |
750,000 |
5.35 |
41" |
35" |
79" |
1,779 |
3" |
BO-700 |
19" |
24" |
25" |
| B850 |
850,000 |
6.07 |
41" |
35" |
85" |
1,973 |
3" |
BO-701 |
19" |
24" |
25" |
| B1050 |
1,050,000 |
7.50 |
52" |
38" |
89" |
3,059 |
4" NPT |
BO-702 |
19" |
24" |
25" |
Boiler Technology
INOV8 International, Inc. manufacturers the premiere line of waste
oil burning equipment. Our patented systems provide an EPA approved
method of disposing of used oils, while solving the disposal and liability
concerns. Waste oil boiler systems are rapidly growing in popularity
due to the great flexibility and benefits they provide when used in
a variety of applications where hot water is needed.
Burning used oils has been popular for nearly two decades but it
hasn't been until recently that technology has advanced to allow
the safe and clean burning of these oils. The detergency package
inherent to waste oil along with the accumulated wear metals from
the engines constitutes many non-burnables that end up as an ash
through the combustion process. It is necessary and critical to
have a cleanable boiler to accommodate the frequent cleaning. INOV8
has selected a high quality, high efficiency boiler that is cleanable.
Simply remove two bolts and swing out the burner door to expose
all of the passageways for cleaning with a brush and vacuum cleaner
and allow the boiler to be placed back in service within fifteen
minutes. Through our continued development work we have learned
of many situations associated with the burning of waste oil in a
boiler. INOV8 has included solutions in our standard boiler product
line for all situations. In fact, we are so convinced of the necessity
of these various solutions that we will not sell a boiler unless
all recommended modifications are included in the installation.
Even with these cost-adding modifications, the INOV8 boiler remains
cost effective and very competitive.
Many waste oil burner manufacturers have attempted to arbitrarily
use their burners with boilers without success or an understanding
why they failed. Evidence of this can be seen in the constant changing
of boilers selected by waste oil burner manufacturers. None of the
systems can match the quality, workmanship, warranty, flexibility,
efficiency and safety provided by the combination INOV8/Buderus
waste oil boiler systems. INOV8 selected Buderus boilers after extensive
testing starting in 1992 and continues to use them today. We sponsored
several field studies in which boiler systems were installed at
customer sites that were monitored closely by INOV8. Through those
experiences we learned of the importance of proper installation,
proper boiler temperatures, proper cleaning procedures, necessary
controls, required safety devices, and a series of modifications
to both the boiler and burner to allow efficient and safe operation
while burning used crankcase oils. |
| Features |
- Factory assembled cast iron section (can be ordered knocked-down)
- Supply and return connections at rear of boiler
- Flexible GL-180M cast iron with silicon “barrier skin”
- Precision casting eliminates need for manual grinding
- Tongue and groove flueside sealing for pressurized operation
- Boiler installation manual
- Modifications to boiler door & liner
- Floating pickup assembly, includes: filter housing, check valve,
float on oil line
|
- Jacket packaged separately in box
- Full-size burner door hinged left or right (field adjustable)
- Blue enamel jacket with 3 ½” wrap-around thermal
insulation
- No refractory or target cup needed due to chamber geometry
- Precision machined steel push nipple sectional construction
- Boiler brush
- Appropriately sized burner
- Appropriately sized draft inducer
- INOV8 boiler instruction manual
- Spare fuses
|
|